Copeland discus compressor nomenclature pdf
Copeland discus compressor nomenclature pdf. a external inherent protection. p. The BOM (Bill of Material) indication is part of the nomenclature. Copeland Discus Series air compressor pdf manual download. nomenclature • cr7, cr6, crkf models - x x x - x x x Product Variations Numbers will be assigned as follows: 1. 5 tfe 7. 21. In fact, Discus compressors have led the industry in energy efficiency for decades, delivering up to 12. Discus digital model numbers include additional information about the compressor, consistent with the standard Discus model - Discus™ reciprocating compressor range - Copeland compressor electronics for Copeland Stream semi-hermetic compressors - Copeland Stream with compressor electronics, semi-hermetic reciprocating compressors - Copeland Stream digital with compressor electronics for continuous capacity modulation - Copeland Stream compressors with compressor The scroll nomenclature, as given on the nameplate of the compressor, contains information such as compressor model family, application, capacity and other specifications. The model 100 = std. Copeland_discus_model_chart. Its optimized Discus™ valve plate design provides the highest energy efficiency. 5 2da3-075e tfc med / high r404a 2da3-r-89ke 7. 800 = std. This database includes both air conditioning and refrigeration products used in a variety of HVACR applications. Nomenclature Factory built Discus compressors with an S/E (the last 3 We make it even easier to upgrade to a Copeland 3D digital Discus semi-hermetic compressor from competitive compressor models with our conversion kit, which includes a suction adapter, compressor mounting, and accessory components. 5 Copeland Discus™ III to Copeland Discus II cross reference matrix Use this matrix to determine required accessory kits if you are replacing a field-failed Copeland Discus III compressor with a Copeland Discus II service model. In fact, Discus? compressors have led the industry in energy efficiency for decades, delivering up to 12. Also for: Copeland 4dadf47ke-tsk, Copeland 4djxr28me-tsk, Copeland 6djxr40me-tse. use on Copeland™ 2D, 3D, 4D and 6D Discus compressors and integrates a number of important sensing and compressor protection functions. 01/0806-0108/E 10/27 Technical Information 3 DWM Copeland Semi-Hermetic Discus Models Capacity Control All Discus model compressors can be equipped with capacity control. •Remove refrigerant from both the high and low side of the compressor. comments copeland discus model cross from old to new model numbers 2df 2da3-0750 tfc a/c r-22 2da3-r-89ko 7. 5 not avail for us oem market tfd med r-502 7. This bulletin covers the application parameters recommended for operating these compressors properly. and component parts 201 = 201 and larger will be assigned for all other variations. g. pdf), Text File (. Standard Model 3 H. units. If this is the case, unloading kits (2 kits will be sent *) will be required. View and Download Emerson Copeland Discus Series application manuallines online. Aug 6, 2018 · on Copeland™ 2D, 3D, 4D and 6D Discus compressors and integrates a number of important sensing and compressor protection functions. Nomenclature . Now a new application of the patented Discus valve D7. A3R85KL-TFD-C00. View and Download Emerson COPELAND 3DSDR17ME-TFD manual online. Copeland compressors are suitable for a wide range of applications either in the form of single compressors, condensing units or as multi-compressor equipment. Some key components for the CoreSense Protection module are labeled in Figure 1 and Figure 2 at the end of this bulletin. Nomenclature Factory built Discus compressors with an S/E (the last 3 IMPORTANT SAFETY INFORMATION Those involved in the design, manufacture, and installation of a system, system purchasers, and service personnel added to the compressor at the time of install. - Ensure that materials and wiring do not touch high temperature areas of the compressor. P. The high pressure refrigerant Discus ™ compressor has a model designation as follows, with the second digit shown as a ' P ': 3. replacement compressor and component. Use a recovery machine and cylinder Exits Compressor Nomenclature The Copeland Discus digital compressor model numbers are designated by a “D” or an “X” in the fourth character, e. Read more A/C DUTY COMPRESSORS COPELAMETIC R12, R22, R502 Nom. Below is a comparison between various Emerson Climate Technologies/Copeland New Discus III Semi-hermetic compressor models and existing Discus II models. Equipped with CoreSense Protection, Copeland Discus compressors are also built to last, saving even more money in maintenance and service calls. – Table 2: Copeland™ Compressors Family Nomenclature Links The contents of this publication are presented for informational purposes only and are not to be construed as warranties or guarantees, express or implied, Cooling Requirements for Copelametic™ and Copeland Discus™ Compressors Table 4 Nomenclature Scheme to Identify Copeland Discus II Compressor Models without Copeland_discus_model_chart. Old Discus Nomenclature Example: 3DS3A150E-TFD New Discus Nomenclature Example: 3DS3R17ME-TFD With the ability to modulate infi nitely between 10 –100% of rated capacity, digital Discus compressors match the system load requirements precisely while consuming less energy and increasing the life of compressor and other system components. comp. 200 = std. H. Communication On Every Discus Copeland Discus With CoreSense Diagnostics Applied Cost Savings - Integration Of Traditional Accessories - Reduced Wiring - Reduced Assembly Labor Advanced Diagnostics Improved Reliability - Reduced Warranty Costs Communications All 2D, 3D, 4D & 6D Copeland Discus Compressors Have CoreSense Technology On Board Mar 18, 2010 · discus compressor cross reference current model # voltage temp refrig new model # h. 5 currently available tfd med / high 507 7. •Keep all non-essential personnel away from the compressor during service. 120 volt control. 2% more energy efficiency than any reed compressor technology. The Copeland Discus Cheat Sheets will help you identify what configuration a compressor is by model number and this will help you select the correct service replacement model. 1. used in copeland cond. pdf - Free download as PDF File (. Copeland Mobile Copeland™ Mobile App (July 31, 2014) The Copeland Mobile smartphone app provides on-the-go access to Emerson Climate Technologies Online Product Information (OPI) database for Copeland compressor specifi cations. •Allow time for the compressor to cool before servicing. 240 volt control. The document provides a nomenclature chart for Copeland Discus compressors that explains the codes used to identify key product details like application range, variations, capacity, electrical specifications, and protection features in 3 letters or fewer. The compared models have similar displacements and will use the same motor/protector combinations. Also for: Copeland k series, Copeland l series, Copeland s series, Copeland 2d series, Copeland 3d series, Copeland 8d series, Copeland 6t series, cylinder Discus compressors have been released at this time. one protector, (line break). COPELAND 3DSDR17ME-TFD air compressor pdf manual download. . 4D Discus Nomenclature various Discus nomenclature specifications. Turner: Date . Special applications are addressed with a selected range of 2-stage, Booster and tandem compressors. The following overview shows an example of the structure of the nomenclature for a fixed-speed scroll Protect your investment with Copeland DISCUS COMPRESSOR REPLACEMENT GUIDE 2D Discus Nomenclature 3D Discus Nomenclature 4D Discus Nomenclature 6D Discus Nomenclature Model - Displacement + Model - Displacement + Model - Displacement + Model - Displacement + Standard/ Med Temp 2DC 2DD 2DL 2DA Standard 3DA 3DB 3DF 3DS Standard Model 4DA 4DB 4DH 4DJ Subject: New Discus (DIII) Assistance letter (4D-6D Models) Dear Mr. P. txt) or view presentation slides online. 3DSDR17ME-TFD, 4DADF47KE-TSK or 4DJXR28ME-TSK, 6DJXR40ME-TSE. 1. *Digital compressors (6DKXF93KL-TSK-A00/this digit of the Discus III nomenclature is X) will only receive one kit. 4D Kit # Do I need this kit? Check the Discus III nomenclature CoreSense™ Kit includes: Special notes Protection •M ulti-Compressor Racks 24 • Water-Cooled Condensing Units 28 Compressor Overview 32 • Scroll Compressors 36 • Semi-Hermetic Reciprocating Compressors 42 • Hermetic Integral Horsepower Reciprocating Compressors 46 • Hermetic Fractional Horsepower Re ciprocating Compressors 50 Core Offerings Commercial Air Conditioning Copeland Discus® compressors have long set the standard as the most trusted name for refrigeration, leading the industry in energy efficiency and reliability for decades. 801 = std. Digital applications run one unloader head and one digital head. Equipped with CoreSense? Protection, Copeland Discus compressors are also built to last, saving even more money in maintenance and service calls. COPELAMETIC R12, R22, R502 507 Electrical Data Copeland Discus Digital™ compressors with CoreSense™ Technology High efficiency Copeland Discus Digital ™ compressors with CoreSense technology offer digital modulation as the most precise method of capacity control to eliminate traditional compressor cycling modulation problems like uneven cooling and reduced compressor life. Number –230 indicates a standard compressor B/M and model number. icub mve fguux lrbjipv vvvv hbqs ixkc jfvmh xvhe euvmv